The Keysight 432A provides high accuracy over a wide temperature range. By measuring the output voltage of the thermistor bridges and computing the corresponding power, even higher accuracy of ±0.2 percent ±0.5 microW can be obtained. Accuracy can be maintained on even the most sensitive range because the error due to thermoelectric effect is reduced to a negligible level.

  • Power Range: 7 ranges with full-scale readings of 10, 30 100 and 300 uW 1, 3 and 10 mW; also calibrated in dBm from -20 dBm to +10 dBm full scale in 5 dB steps
  • Noise: Less than 0.25% of full scale peak (typical)
  • Response Time: At recorder output, 35 ms time constant (typical)
  • Fine Zero: Automatic, operated by front-panel switch
  • Zero Carryover: Less than 0.50% of full scale when zeroed on most sensitive range
  • Meter: Taut-band suspension, individually calibrated, mirror-backed scales. Milliwatt scale more than 100 mm (4.25 in) long
  • Calibration Factor Control: 13-position switch normalizes meter reading to account for thermistor sensor calibration factor. Range 100% to 88% in 1% steps
  • Thermistor Sensor: Thermistor sensors are required for operation of the 432A.

Ordering Information
HP 432A Power Meter
Opt 001 Rechargeable battery installed, provides up
to 20 hours of continuous operation (HP 432A only)
Opt 002 Input connector placed on rear panel in
parallel with front
Opt 003 Input connector on rear panel only
Opt 009 3.1 m (10 ft) Cable for 100 Ω or 200 Ω Sensor
Opt 010 6.1 m (20 ft) Cable for 100 Ω or 200 Ω Sensor
Opt 011 15.2 m (50 ft) Cable for 100 Ω or 200 Ω Sensor
Opt 012 30.5 m (100 ft) Cable for 100 Ω or 200 Ω Sensor
Opt 013 61 m (200 ft) Cable for 100 Ω or 200 Ω Sensor
Opt 100 100 Vac Operation, 48 to 66 Hz
Opt 910 Extra Operating and Service Manual
(HP432A: p/n 00432-90009)
Opt W30 Extended Repair Service (see page 71)
Opt W32 Calibration Service (see page 71)
HP 8477A Power Meter Calibrator
Opt W30 Extended Repair Service (see page 71)
Opt W32 Calibration Service

    회사명

    부서명

    구매문의판매문의렌탈문의수리문의교정문의

    전화상담방문상담견적서상담

    문의 및 요청내용 *

    개인정보 수집, 이용 및 처리방침

    - 수집항목: 이름, 연락처, 이메일, 주소
    - 수집/이용목적: 견적요청에 대한 접수 및 결과 회신
    - 이용기간: 원칙적으로 개인정보 수집 및 이용목적이 달성된 후에는 해당 정보를 지체 없이 파기합니다.
    단, 관계법령의 규정에 의하여 보전할 필요가 있는 경우 일정기간 동안 개인정보를 보관할 수 있습니다.

    그 밖의 사항은 (주)누비콤 개인정보취급방침을 준수하며 견적서를 요청하면 개인정보처리방침에 동의하는 것으로 간주됩니다.

    • 개인정보처리방침에 동의합니다.