DC-18GHz 24V RF Coaxial Switch

Frequency ­4 ­8 (GHz) V.S.W.R. 1.15 1.25 (max.) Insertion loss 0.2 0.3 (dB. max.) Isolation 80 70 (dB. min.)

Wireless and mobile communication infrastructure Cellular phone base stations Amplifier switching Measurement instruments All types of inspection equipment

2. SPDT and transfer type available 3. High sensitivity Nominal operating power: 840 mW (SPDT, Failsafe type) 1540 mW (Transfer, Failsafe type) 4. Long life: × 106 (SPDT)

Arrangement Contact material Initial contact resistance Rating Indicator rating Contact input power*1 Contact rating Initial contact resistance (Measured 5V 100mA) V.S.W.R. (max.) Insertion loss (dB, max.) Isolation (dB, min.) Mechanical (at 180 cpm) Electrical (at 20 cpm) Transfer Gold plating Max. 120W 3GHz (V.S.W.R 1.15 or less, no contact switching, ambient temperature 40°C [SPDT], 25°C [Transfer]) Max. 30V 100mA Max. 5V 100mA Max. to 1 GHz to 3GHz, impedance 50, V.S.W.R.; max. to 3GHz, impedance 50, V.S.W.R.; max. to12.4 to SPDT

High frequency characteristics (Impedance 50) Expected life (min. operation)

SPDT Initial insulation resistance*2 Between open contacts Between contact and coil Initial breakdown voltage*3 Between contact and earth terminal Between coil and earth terminal Operate time*4 (at 20°C) Functional*5 Shock resistance Destructive*6 Functional*7 Vibration resistance Destructive Ambient temp Conditions for operation, transport and storage*8 (Not freezing and condensing at low temperature) Humidity Unit weight (Approx.) Remarks

*1 Please verify the usability of input power under actual conditions because heat generated from connectors can influence connection. *2 Measurement at same location as “Initial breakdown voltage” section. *3 Detection current: 10mA *4 Nominal operating voltage applied to the coil, excluding contact bounce time.

Transfer Min. M 500 Vrms for 1 min. 500 Vrms for 1 min. 500 Vrms for 1 min. 500 Vrms for 1 min.
Max. Hz at double amplitude Hz at double amplitude to 85% R.H. 110g 3.88oz

Half-wave pulse of sine wave: 11ms, detection time: 10µs. Half-wave pulse of sine wave: 11ms Detection time: 10µs Refer to 4. Conditions for operation, transport and storage mentioned in NOTES.

Nominal operating voltage, to 18GHz (SPDT) 00: Failsafe 4H: 4.5V (Failsafe, to 18GHz (Transfer) 20: Latching type only) to 26.5GHz (SPDT) 51: Latching with TTL driver 05: 5V (Latching with to 26.5GHz (Transfer) (with self cut-off function) TTL driver type only) 24: 24V Frequency Operating function

    회사명

    부서명

    구매문의판매문의렌탈문의수리문의교정문의

    전화상담방문상담견적서상담

    문의 및 요청내용 *

    개인정보 수집, 이용 및 처리방침

    - 수집항목: 이름, 연락처, 이메일, 주소
    - 수집/이용목적: 견적요청에 대한 접수 및 결과 회신
    - 이용기간: 원칙적으로 개인정보 수집 및 이용목적이 달성된 후에는 해당 정보를 지체 없이 파기합니다.
    단, 관계법령의 규정에 의하여 보전할 필요가 있는 경우 일정기간 동안 개인정보를 보관할 수 있습니다.

    그 밖의 사항은 (주)누비콤 개인정보취급방침을 준수하며 견적서를 요청하면 개인정보처리방침에 동의하는 것으로 간주됩니다.

    • 개인정보처리방침에 동의합니다.