리퍼비시 계측기

리퍼비시 계측기

FNS-AX4-B63

  • ModelFNS-AX4-B63
  • MakerNoiseken
  • DescriptionFast Transient / Burst Simulator
  • Rental문의요망
  • Stock문의요망
  • IEC 61000-4-4 Ed.3 standard compliance.
  • Pre-check function equipped, making. inspection before testing easier.
  • Normal mode test support. for testing for real field troubles. (option)
  • Utilize an outlet box that simplifies EUT connection. (option)
  • Compared with conventional products, the size has become compact. (Approximately 67% by volume)
  • Easy to understand Panel display reduces mistakes in connecting power cables.
  • Windows compatible software control. (option)
  • Next calibration date notification. (Windows software only)
  • LCD screen with multi-language support and enhanced operability.
  • Maximum output voltage of 5 kV and maximum pulse frequency of 2 MHz allowing to test above the standard test level.
  • CDN capacity is increased to single phase type AC 240 V 20 A, single and three phase type to AC 600 V 63 A, supporting a wider range of EUTs.
  • Large capacity CDN (100 A or 150 A) option available for Injection test on various EUTs.
  • Using coupling clamps and EMS probe kit, allows to test signal lines and evaluate noise immunity on PCBs. (option)

■ Generator specifications

Parameter Specification / Function
Output voltage 200 to 5000 V 10 V Step
Polarity Positive or negative, polarity alternation possible per burst
Repetition frequency 0.1 kHz to 2000 kHz
0.1 kHz to 1 kHz / 0.01 kHz step Tolerance ± 5%, 1.0 kHz to 10 kHz / 0.1 kHz step Tolerance ± 5%
10 kHz to 100 kHz / 1 kHz step Tolerance ± 5%, 100 kHz to 1000 kHz / 10 kHz step Tolerance ± 5%
1000 kHz to 2000 kHz / 100 kHz step Tolerance ± 10%,  (Limitation per voltage levels when continuous output)
Number of pulses 1 to 1000 at a step of 1 pulse , Setting limit: 1 pulse per ms in a burst (repetition frequency 1 kHz or more)
Burst duration Formula for Burst duration = Pulse number / Repetition Frequency
Scope of manually setting value for burst duration: 0.01 to 999 ms
Burst period 10 to 1000ms ± 10% 10ms steps   (500ms or more for polarity alternate mode)
Polarity alternate function Output polarity alternated between positive and negative at each burst period
Setting condition: the burst period is 500ms or more and the burst pause period [ (burst period) – (burst duration)] is 100ms or more
Maximum test time: 10 minutes
Continuous Pulse output Up to 1000 V -10 kHz or less, to 2000 V -4 kHz or less, to 5000 V -1 kHz or less. Maximum test time for each case: 10 min
Frequency modulation Frequency is shifted continuously between set frequency and approximately -10% from the set frequency. The modulating wave is triangular wave of approximately 20Hz
External trigger External trigger input invokes 1 burst output in synchronization with the trigger input. Trigger specification: Hi (+ 5V) → Lo (0 V) triggers one burst period.
Pulse waveform (at 50 Ω load) Pulse peak voltage: (set voltage / 2) ± 10% Rise time: 5 ns ± 30% Pulse width: 50 ns ± 30%
Pulse waveform (at 1 kΩ load) Pulse peak voltage: (set voltage x 0.95) ± 20% Rise time: 5 ns ± 30% Pulse width: 35 to 150 ns
DC blocking capacitor 10nF ± 20%

 

■ CDN specifications

Parameter Specification / Function
Power capacity A 20 model: single phase AC 240 V / 20 A, DC 125 V / 20 A (10 A for PE)
B 63 model: three-phase AC 600 V / 63 A, DC 125 V / 63 A (10 A for N / PE)
Applied phase A20 model: L / N / PE B63 model: L1 / L2 / L3 / N / PE Single line or all lines can be specified individually for each phase
Injection mode Common mode (Normal mode available using option)
EUT Line input/output φ6 mm safety socket
Coupling capacitor 33 nF
Output waveform specification Pulse peak voltage: (set voltage) / 2 ± 10% Rise time: 5.5 ns ± 1.5 ns Pulse width: 45 ns ± 15 ns
Set voltage ± 4000 V, frequency specified from 5 kHz to 100 kHz
Input residual voltage 10% or less of setting pulse voltage EUT line input is 50 Ω termination, line output is defined as open
AC Line Sync Synchronous and asynchronous setting available.
Setting phase angle: 0 to 360 ° ± 10 ° 1 °Step Synchronizable voltage: AC 85 V to rated voltage
Reference phase: between L-N (A20 model), L1-L2 (B63 model)

 

■ Other specifications

Parameter Specification / Function
Emergency stop Push lock type switch (Test stop, EUT line OFF)
EUT FAIL function FAIL signal from external (Hi → Lo) detected during test
FAIL signal specifications VLO: 0 V, VHI: + 5 V
Choose operation from test stop / pause when triggered  3 channels available for the FAIL input
External interface REMOTE (For external PC control), CDN I/F (For external CDN), INDICATOR (For Warning Lamp or indicator lamp)
EUT FAIL INPUT (For temporary pause at EUT failure event)
Accessories Power Cable, SG Cable, Line Input Cable, Output Cable, Waveform Check Connector, Coaxial Cable,
Operation Manual, Accessoriesies bag
Operating environment Temperature 15 to 35 °C  Relative humidity 25 to 75%
External Dimensions / Weight (W)430 x (H)199 x (D)370 mm (excluding protrusions) / Approximately 14 kg (A20 model) and 22 kg (B63 model)
Power supply AC 100 to 240 V ± 10% 50/60 Hz approx. 120 VA

    회사명

    부서명

    구매문의판매문의렌탈문의수리문의교정문의

    전화상담방문상담견적서상담

    문의 및 요청내용 *

    개인정보 수집, 이용 및 처리방침

    - 수집항목: 이름, 연락처, 이메일, 주소
    - 수집/이용목적: 견적요청에 대한 접수 및 결과 회신
    - 이용기간: 원칙적으로 개인정보 수집 및 이용목적이 달성된 후에는 해당 정보를 지체 없이 파기합니다.
    단, 관계법령의 규정에 의하여 보전할 필요가 있는 경우 일정기간 동안 개인정보를 보관할 수 있습니다.

    그 밖의 사항은 (주)누비콤 개인정보취급방침을 준수하며 견적서를 요청하면 개인정보처리방침에 동의하는 것으로 간주됩니다.

    • 개인정보처리방침에 동의합니다.