리퍼비시 계측기

리퍼비시 계측기

MR8827

  • ModelMR8827
  • MakerHioki
  • DescriptionMEMORY HiCORDER MR8827
  • Option8966×16,L9197×32,MR9321-01×8,U8330,U8350..
  • Rental문의요망
  • Stock문의요망

Hioki Memory HiCorders are high-speed waveform monitoring and recording devices that can simultaneously measure multiple physical phenomena such as voltage, current, temperature, vibration, weight, acceleration and rotation due to complete isolation between channels and from each channel to the ground. More than just a digital oscilloscope, the MR8827 data acquisition (DAQ) recorder accommodates plug-and-play input modules to meet applications such as trial runs after the scheduled maintenance of railway cars to verify for voltage command signals, motor current, car speed, and brake pressure.

Max. Number of channels 32 ch analog + 32 ch logic, or 28 ch analog + 64 ch logic (when use with built-in logic input + plug-in logic unit 8973 × 2)
Number of slots 16 slots (Max. 16)
Number of logic channels 32 ch logic (logic probe terminal GND share a common GND with chassis) Built-in logic input not available when using DVM Unit MR8990 on slots 1, 2, 9, or 10.

[Limitation on using built-in logic input] (with logic measurement ON)
• Measurement resolution on slots 1, 2, 9, and slot 10 is limited up to 12 bits
• Cannot use Frequency Unit 8970 on slots 1, 2, 9, or 10

Measurement ranges (20 div full-scale) [Analog Unit 8966]: 5 mV/div to 20 V/div, 12 ranges, resolution : 1/100 of range (using 12-bit A/D)
[High Resolution Unit 8968]: 5 mV/div to 20 V/div, 12 ranges, resolution : 1/1600 of range (using 16-bit A/D)
Max. allowable input 400 V DC (using the 8966/8968)
Frequency characteristics DC to 5 MHz (-3 dB, using the 8966), DC to 100 kHz (-3 dB, using the 8968)
Time axis (Memory function) 5 µs to 5 min/div, 26 ranges, at 100 points/div resolution
Measurement functions Memory (high-speed recording), Recorder (real-time recording), X-Y recorder, FFT
Other functions Numerical calculation, Waveform processing, Waveform judgment (at Memory, or FFT function)
Memory capacity 128M-words/ch (using 4 Analog channels) to 16M-words/ch (using 32 Analog channels), Total capacity 512MW memory
Data storage media USB memory stick, CF card, Built-in SSD unit (option, 128GB) *Approx. 125 sec. when saving 100 MB of data
*Data of 100 MB in size can record 16,000 div waveforms across 32 channels.
Printing [Built-in A4-size printer option]: 216 mm (8.50 in) × 30 m (98.43 ft), thermal paper roll, Recording speed : Max. 50 mm (1.97 in)/s
Display 10.4 inch TFT color LCD (SVGA, 800 × 600 dots)
External interfaces LAN: 100BASE-TX, USB 2.0 series A receptacle 2 port (for USB memory, mouse)
USB 2.0 series B receptacle (for communication with PC, mass storage)
Power supply 100 V to 240 V AC, 50/60 Hz (220 VA max., when using printer: 350 VA max.)
Dimensions and mass 401 mm (15.79 in)W × 233 mm (9.17 in)H × 388 mm (15.28 in)D (including protruding parts except handle), 12.6 kg (444.4 oz) (main unit only)
Included accessories Instruction manual ×1, Power cord ×1, Application disk (CD-R) ×1, Input cord label ×1, Printer paper ×1 (when ordering printer unit), Roll paper attachment ×2 (when ordering printer unit)

LabVIEW and MATLAB support

 
Compatible models LabVIEW MATLAB script
MR8827 Available Available

ANALOG UNIT 8966×16

L9197×32

LOGIC PROBE MR9321-01×8

U8330

U8350

    회사명

    부서명

    구매문의판매문의렌탈문의수리문의교정문의

    전화상담방문상담견적서상담

    문의 및 요청내용 *

    개인정보 수집, 이용 및 처리방침

    - 수집항목: 이름, 연락처, 이메일, 주소
    - 수집/이용목적: 견적요청에 대한 접수 및 결과 회신
    - 이용기간: 원칙적으로 개인정보 수집 및 이용목적이 달성된 후에는 해당 정보를 지체 없이 파기합니다.
    단, 관계법령의 규정에 의하여 보전할 필요가 있는 경우 일정기간 동안 개인정보를 보관할 수 있습니다.

    그 밖의 사항은 (주)누비콤 개인정보취급방침을 준수하며 견적서를 요청하면 개인정보처리방침에 동의하는 것으로 간주됩니다.

    • 개인정보처리방침에 동의합니다.