리퍼비시 계측기

리퍼비시 계측기

Others

MT220 (767603)

  • ModelMT220
  • MakerYokogawa
  • DescriptionDigital Manometers
  • Rental문의요망
  • Stock문의요망

The MT220 can measure pressure with outstanding accuracy, high resolution, minimal tempco, and excellent stability. It offers a wealth of functions for field calibration, including transmitter output measurement (DCV/DCA functions), 24-V DC output, percent error readout, measurement data memory, and Ni-Cd battery operation. The D/A conversion output makes it simple to output data to a recorder or other equipment. And of course, data output through a GP-IB or RS-232 interface is also possible-including data output during operation on a 12 V DC power supply or Ni-Cd batteries..

●High accuracy: ±0.01% of reading, with a maximum allowable input of 500 kPa (130 kPa-range model)

●Measurement with DCV and DCA

● 24 V DC output

●Percent reading

● Error reading

● Measurement data memory

●D/A conversion output, comparator output, and external trigger input (optional)

 

Display LCD display (with backlight) 5.5 digits or 4.56 digits.
Warm-up Time approx. 5 minutes
Operating Temperature Ranges 5°C to 40°C; 20% to 80% RH (no condensation)
Storage Temperature -20°C to 60°C
Power Supply AC, DC, Ni-Cd batteries (optional)
AC Power Rating 100 to 120/200 to 240 Volts AC, at 50/60Hz
Allowable Supply Voltage Range 90 to 132V/180 to 264V AC
DC Power Rating 10 Volts to 15 Volts DC
Battery Pack (Optional) Ni-Cd batteries: Last approx. 10 hours in continuous operation mode when fully charged (tested with backlight turned On).
Battery charger: Built-in the MT210/MT210F main units.
Recharge time: approx. 12 hours.
Power Consumption When in pressure measurement mode: 25 VA max. for 100-V
power line; 40 VA max. for 200-V power line
When in recharge mode: 45 VA max. for 100-V power line; 65 VA
max. for 200-V power line
When in DC-powered operation: 10 VA max.
Insulation resistance 20 MΩ min. at 500 V DC, between AC power supply and casing.
Withstand Voltage 1500V AC (50/60Hz) for 1 minute, between AC power supply and casing.
Dimensions Main Unit: approx. 132mm x 213mm x 350mm (excluding protrusions)
Battery Pack (Optional): 33mm x 182mm x 260mm (excluding protrusions)
Weight Main Unit: See the main specifications in Pressure Measurement section (PDF Datasheet).
Battery Pack: approx. 2.7kg

    회사명

    부서명

    구매문의판매문의렌탈문의수리문의교정문의

    전화상담방문상담견적서상담

    문의 및 요청내용 *

    개인정보 수집, 이용 및 처리방침

    - 수집항목: 이름, 연락처, 이메일, 주소
    - 수집/이용목적: 견적요청에 대한 접수 및 결과 회신
    - 이용기간: 원칙적으로 개인정보 수집 및 이용목적이 달성된 후에는 해당 정보를 지체 없이 파기합니다.
    단, 관계법령의 규정에 의하여 보전할 필요가 있는 경우 일정기간 동안 개인정보를 보관할 수 있습니다.

    그 밖의 사항은 (주)누비콤 개인정보취급방침을 준수하며 견적서를 요청하면 개인정보처리방침에 동의하는 것으로 간주됩니다.

    • 개인정보처리방침에 동의합니다.