RSA5106B

  • ModelRSA5106B
  • MakerTektronix
  • DescriptionRSA5000 Series Spectrum Analyzer
  • Option09, 80, 86, B16X
  • Rental문의요망
  • Stock재고있음
모든 애플리케이션에 적합한 실시간 스펙트럼 분석기

중간급의 RSA 5000 시리즈 스펙트럼 분석기는 동급 최고의 RF 성능과 최대 165MHz인 대역폭, 6세대 DPX® 기술이 결합된 제품으로, 일상적 작업에 필요한 측정 신뢰성 및 기능과 함께 까다로운 스펙트럼 분석 측정에 필요한 동적 범위를 제공합니다.

  100% POI의 최소 이벤트 기간 실시간 대역폭 주파수 범위
RSA5106B 0.434μs 25 MHz, 40 MHz, 80 MHz, 125 MHz 및 165 MHz 1 Hz ~ 6.2 GHz

Specifications

All specifications are guaranteed unless noted otherwise. All specifications apply to all models unless noted otherwise.

Model overview

  RSA5103B RSA5106B RSA5115B RSA5126B
Frequency range 1 Hz – 3 GHz 1 Hz – 6.2 GHz 1 Hz – 15 GHz 1 Hz – 26.5 GHz
Real-time acquisition bandwidth 25 MHz, 40 MHz, 85 MHz, 125 MHz, 165 MHz
Minimum Event Duration for 100% POI at 100% amplitude

2.7 μs at 165 MHz BW (0.434 us, Opt. 300)

2.8 μs at 85 MHz BW (0.551 us, Opt. 300)

3.0 μs at 40 MHz BW (0.79 us, Opt. 300)

3.2 μs at 25 MHz BW (0.915 us, Opt. 300)

SFDR (typical) >75 dBc (25/40 MHz)

>73 dBc (85/165 MHz)

≥ 80 dBc (Opts. B85HD, B125HD, B16xHD)

Trigger modes Free run, Triggered, FastFrame
Trigger types Power, Frequency mask, Frequency edge, DPX density, Runt, Time qualified

Frequency related

Reference frequency
Specification Standard Option PFR Conditions
Initial accuracy at cal ± 1 x 10 -6 ± 1 x 10 -7 After 10 minute warm-up
Aging per day 1 x 10 -8 1 x 10 -9 After 30 days of operation
First year aging (typical) 1 x 10 -6 7.5 x 10 -8 After 1 year of operation
Aging per 10 years   3 x 10 – 7 After 10 years of operation
Temperature drift 2 x 10 -6 1 x 10 -7 From 5 to 40 °C
Cumulative error (temperature + aging, typical) 3 x 10 -6 4 x 10 -7 Within 10 years after calibration
Reference output level >0 dBm (internal or external reference selected), +4 dBm, typical
External reference input frequency
Every 1 MHz from 1 to 100 MHz plus 1.2288 MHz, 4.8 MHz, and 19.6608 MHz.
External input must be within ± 1 x 10 -6 (Std), ± 3 x 10 -7 (Opt PFR) to stated input
External reference input frequency requirements
Spurious level on input must be < –80 dBc within 100 kHz offset to avoid on-screen spurs
Spurious < –80 dBc within 100 kHz offset Input level range –10 dBm to +6 dBm
Center frequency setting resolution 0.1 Hz
Frequency marker readout accuracy ±(RE × MF + 0.001 × Span + 2) Hz (RE = Reference frequency error) (MF = Marker frequency (Hz))
Span accuracy
±0.3% of span (Auto mode)

Trigger related

Trigger event source RF input, Trigger 1 (front panel), Trigger 2 (rear panel), Gated, Line
Trigger setting Trigger position settable from 1 to 99% of total acquisition length
Trigger combinatorial logic Trigger 1 AND trigger 2 / gate may be defined as a trigger event
Trigger actions Save acquisition and/or save picture on trigger

Power level trigger

Level range 0 dB to –100 dB from reference level
Accuracy For trigger levels >30 dB above noise floor, 10% to 90% of signal level
Level ≥ –50 dB from reference level ±0.5 dB From < –50 dB to –70 dB from reference level ±1.5 dB
Trigger bandwidth range At maximum acquisition bandwidth
Standard (Opt. B25) 4 kHz to 10 MHz + wide open
Opt. B40 4 kHz to 20 MHz + wide open
Opt. B85/B16x 11 kHz to 40 MHz + wide open
Trigger position timing uncertainty
25/40 MHz acquisition BW, 20 MHz trigger BW Uncertainty = ±15 ns
25/40 MHz acquisition BW, Max Trigger BW Uncertainty = ±12 ns
85/125/165 MHz acquisition BW, 60 MHz Trigger BW Uncertainty = ±5 ns
85/125/165 MHz acquisition BW, Max Trigger BW Uncertainty = ±4 ns
Trigger re-arm time, minimum (fast frame on)
10 MHz acquisition BW ≤25 μs
40 MHz acquisition BW ≤10 μs
85/125 MHz acquisition BW ≤5 μs
165 MHz acquisition BW ≤5 μs
Minimum event duration
25 MHz acquisition BW 25 ns
40 MHz acquisition BW 25 ns
85/125 MHz acquisition BW 6.2 ns
165 MHz acquisition BW 6.2 ns

External trigger 1

Level range -2.5 V to +2.5 V
Level setting resolution 0.01 V
Trigger position timing uncertainty 50 Ω input impedance
>20 MHz to 40 MHz acquisition BW ±20 ns
>40 MHz to 80 MHz acquisition BW ±13.5 ns
>80 MHz to 165 MHz acquisition BW ±11 ns
Input impedance Selectable 50 Ω/5 kΩ impedance (nominal)

External trigger 2

Threshold voltage Fixed, TTL
Input impedance 10 kΩ (nominal)
Trigger state select High, Low

Trigger output

Voltage
Output current <1 mA
High >2.0 V
Low <0.4 V

Frequency mask trigger

Mask shape User defined
Mask point horizontal resolution <0.12% of span
Level range 0 dB to –80 dB from reference level
Level accuracy3 0 to –50 dB from reference level ±(Channel response + 1.0 dB) –50 dB to –70 dB from reference level ±(Channel response + 2.5 dB)
Span range
100 Hz to 25 MHz (Opt. B25)
100 Hz to 40 MHz (Opt. B40)
100 Hz to 85 MHz (Opt. B85, B85HD)
100 Hz to 125 MHz (Opt. B125, B125HD)
100 Hz to 165 MHz (Opt. B16x, B16xHD)
Trigger position uncertainty
Span = 25 MHz (Opt. B25)
±13 μs (RBW ≥ 300 kHz)
±7 μs (Opt. 09)
Span = 40 MHz (Opt. B40)
±13 μs (RBW ≥ 300 kHz)
±6 μs (Opt. 09)
Span = 85 MHz (Opt. B85)
±10 μs (RBW ≥ 1 MHz)
±3 μs (Opt. 09)
Span = 165 MHz (Opt. B16x)
±9 μs (RBW ≥ 1 MHz)
±3 μs (Opt. 09)
Minimum signal duration for 100% probability of trigger at 100% amplitude

Ordering information
Models
RSA5103B Real Time Signal Analyzer, 1 Hz to 3 GHz
RSA5106B Real Time Signal Analyzer, 1 Hz to 6.2 GHz
RSA5115B Real Time Signal Analyzer, 1 Hz to 15 GHz
RSA5126B Real Time Signal Analyzer, 1 Hz to 26.5 GHz
All Include: Quick-start Manual (Printed), Application Guide, Printable Online Help File, Programmer’s manual (on CD), power cord, BNC-N adapter,
Front Cover.
RSA5115B also includes: Planar Crown RF Input Connector – Type N Female PN 131-4329-00
RSA5126B also includes: Planar Crown RF Input Connector – 3.5 mm Female
Note: Please specify power plug and language options when ordering.
Warranty One year
Options, accessories, and upgrades
Options
Product Options Description
RSA5103B Real Time Signal Analyzer, 1 Hz to 3 GHz
RSA5106B Real Time Signal Analyzer, 1 Hz to 6.2 GHz
RSA5115B Real Time Signal Analyzer, 1 Hz to 15 GHz
RSA5126B Real Time Signal Analyzer, 1 Hz to 26.5 GHz
Opt. B25 25 MHz Acquisition Bandwidth (no-cost option)
Opt. B40 40 MHz Acquisition Bandwidth
Opt. B85 85 MHz Acquisition Bandwidth
Opt. B125 125 MHz Acquisition Bandwidth
Opt. B16x 165 MHz Acquisition Bandwidth
Opt. B85HD 85 MHz Acquisition Bandwidth, High Dynamic Range
Opt. B125HD 125 MHz Acquisition Bandwidth, High Dynamic Range
Opt. B16xHD 165 MHz Acquisition Bandwidth, High Dynamic Range
Opt. 300 High performance real time (Opt. 09 required)
Opt. 09 Enhanced Real Time
Opt. 10 AM/FM/PM Modulation and Audio Measurements (Opt. 300 required)
Opt. 11 Phase Noise / Jitter Measurement
Opt. 12 Settling Time (Frequency and Phase)
Opt. 14 Noise Figure and Gain (Internal preamp recommended)
Opt. 20 Pulse Measurements
Opt. 21 General Purpose Modulation Analysis
Table continued…
RSA5000 Series Spectrum Analyzers
www.tek.com 54
Product Options Description
Opt. 22 Flexible OFDM Analysis
Opt. 23 WLAN 802.11a/b/g/j/p measurement application
Opt. 24 WLAN 802.11n measurement application (requires opt 23)
Opt. 25 WLAN 802.11ac measurement application (requires opt 24)
Opt. 26 APCO P25 measurement application
Opt. 27 Bluetooth Basic LE Tx Measurements
Opt. 28 LTE Downlink RF measurements
Opt. 31 Bluetooth 5 Measurements
(requires opt 27)
Opt. 32 EMC pre-compliance and troubleshooting
Opt. MAP Mapping and signal strength
Opt. 50 Internal Preamp, 1 MHz to 3/6.2 GHz, RSA5103B/5106B only
Opt. 51 Internal Preamp, 1 MHz to 15/26.5 GHz, RSA5115B/5126B only
Opt. 53 Memory Extension, 4 GB Acquisition Memory Total
Opt. 60 32 Removable SSD, incompatible with Opt. 61
Opt. 6132 Internal HDD, incompatible with Opt. 60 (no cost option)
Opt. 65 Digital I and Q outputs
Opt. 66 Zero-span analog output
Opt. 6566 Digital I and Q outputs and Zero-span analog output
Opt. PFR Precision Frequency Reference
Opt. 54 Signal Classification and Survey

International power plugs
Opt. A0 North America power plug (115 V, 60 Hz)
Opt. A1 Universal Euro power plug (220 V, 50 Hz)
Opt. A2 United Kingdom power plug (240 V, 50 Hz)
Opt. A3 Australia power plug (240 V, 50 Hz)
Opt. A4 North America power plug (240 V, 50 Hz)
Opt. A5 Switzerland power plug (220 V, 50 Hz)
Opt. A6 Japan power plug (100 V, 50/60 Hz)
Opt. A10 China power plug (50 Hz)
Opt. A11 India power plug (50 Hz)
Opt. A12 Brazil power plug (60 Hz)
Opt. A99 No power cord
32 Must order either Opt. 60 or 61.
RSA5000 Series Spectrum Analyzers
www.tek.com 55
Language options
Opt. L0 English manual
Opt. L3 Japanese manual
Opt. L5 Simplified Chinese manual
Opt. L7 Russian manual
Service options
Opt. C3 Calibration Service 3 Years
Opt. C5 Calibration Service 5 Years
Opt. CA1 Single Calibration or Functional Verification
Opt. D1 Calibration Data Report
Opt. D3 Calibration Data Report 3 Years (with Opt. C3)
Opt. D5 Calibration Data Report 5 Years (with Opt. C5)
Opt. G3 Complete Care 3 Years (includes loaner, scheduled calibration, and more)
Opt. G5 Complete Care 5 Years (includes loaner, scheduled calibration, and more)
Opt. R5 Repair Service 5 Years (including warranty)

Recommended accessories
RTPA2A Spectrum Analyzer
Probe Adapter compatibility
Supports TekConnect® probes.
Compatibility: P7225 – 2.5 GHz Active Probe, P7240 – 4 GHz Active Probe, P7260 – 6 GHz Active Probe,
P7330 – 3.5 GHz Differential Probe, P7350 – 5 GHz Differential Probe, P7350SMA – 5 GHz Differential SMA
Probe, P7340A – 4 GHz Z-Active Differential Probe, P7360A – 6 GHz Z-Active Differential Probe, P7380A – 8
GHz Z-Active Differential Probe, P7380SMA – 8 GHz Differential Signal Acquisition System, P7313 – >12.5 GHz
Z-Active Differential Probe, P7313SMA – 13 GHz Differential SMA Probe, P7500 Series – 4 GHz to 20 GHz
TriMode Probes
SignalVu-PC Software based on the RSA5000 Series Real Time Spectrum Analyzers puts the power of your
RTSA signal analysis tools on your Windows 64-bit PC. Performs measurements on stored signals
from RSA3000/5000/6000 series, RSA306/306B, RSA500A/600A series, RSA7100A, and MDO4000B/C
oscilloscope RF captures.
Additional Removable Hard
Drive
Order RSA5BUP Opt. SSD. This is an additional solid-state drive for instrument with Option 56 installed.
(Windows 7 and instrument software preinstalled).
DC Block Order 119-7902-00. 9 kHz-18 GHz. Type N Male to Type N Female. Voltage Rating: 50 V DC Max. Insertion
Loss 0.9 dB. Aeroflex model 7003.
EMI-NF-PROBE Near Field Probe set
Noise source NoiseCom NC346C Series. Provides supported sources up to 55 GHz in a variety of connector types and ENR
values. Contact NoiseCom for full information and to order: http://noisecom.com
RSA5000 Series Spectrum Analyzers
www.tek.com 56
131-4329-xx Planar Crown RF Input Connector – 7005A-3 Type-N Female
600 Ω BNC pass-through Required for higher-speed noise figure measurements when ordering RSA5UP Opt 14 for RSA5000A.
POMONA 4119-600 RF/COAXIAL ADAPTER, BNC PLUG-BNC JACK. Contact Pomona Electronics and
distributors worldwide to order: http://pomonaelectronics.com
131-9062-xx Planar Crown RF Input Connector – 7005A-6 3.5 mm Female
131-8822-xx Planar Crown RF Input Connector – 7005A-7 3.5 mm Male
131-8689-xx Planar Crown RF Input Connector – 7005A-1 SMA Female
015-0369-xx RF Adapter – N (male) to SMA (male)
119-6599-xx Power Attenuator – 20 dB, 50 W, 5 GHz
Transit Case 016-2026-xx
RSA56KR Rackmount Retrofit
Additional Quick-start Manual
(Paper)
071-3224-xx Additional Application
Examples Manual (Paper) 071-3283-xx
EMC accessories available from Com-Power www.com-power.com:
CLCE-400 RF current probe 10 kHz to 400 MHz
ABF-900A Biconical antenna 25 MHz to 300 MHz
ALC-100 Compact Log Periodic antenna 300 MHz to 1 GHz
PAM-103 Preamplifier 1 MHz to 1 GHz
AT-812 Antenna Tripod 0.8 to 1.5m height range
EMC accessories available from Tekbox www.tekbox.com:
TBPS01 Near field probe set, H20, H10, H5, and E5
TBCP1-150 RF current monitoring probe 10 kHz to 250 MHz
TBLC08 Line impedance stabilization network (LISN) 50uH AC
TBOH01 Line impedance stabilization network (LISN) 5uH DC
TBFL1 Transient limiter 150 kHz to 30 MHz
TBWA2 Near field probe amplifier 20 dB

    회사명

    부서명

    구매문의판매문의렌탈문의수리문의교정문의

    전화상담방문상담견적서상담

    문의 및 요청내용 *

    개인정보 수집, 이용 및 처리방침

    - 수집항목: 이름, 연락처, 이메일, 주소
    - 수집/이용목적: 견적요청에 대한 접수 및 결과 회신
    - 이용기간: 원칙적으로 개인정보 수집 및 이용목적이 달성된 후에는 해당 정보를 지체 없이 파기합니다.
    단, 관계법령의 규정에 의하여 보전할 필요가 있는 경우 일정기간 동안 개인정보를 보관할 수 있습니다.

    그 밖의 사항은 (주)누비콤 개인정보취급방침을 준수하며 견적서를 요청하면 개인정보처리방침에 동의하는 것으로 간주됩니다.

    • 개인정보처리방침에 동의합니다.